Default environmental data or FDES: the gap in figures

Méthodologie

Without an FDES, a product enters the building's LCA with deliberately inflated default data. An aluminium window declared at 88 kg CO2e weighs 187 kg with the default value: here is how to read that gap.

Nathan GourdinNovember 4, 2026

When a product has no FDES (fiche de déclaration environnementale et sanitaire, the French environmental and health declaration for construction products), the building's RE2020 calculation uses default environmental data, inflated by 30% to 100% depending on the family. RE2020 is the French environmental regulation for new buildings. In the INIES database, France's national database of environmental declarations, an aluminium window declared at 88 kg CO2e in its FDES weighs 187 kg CO2e with the default value: more than double.

Most manufacturers have heard of this gap without ever putting a figure on it for their own products. Yet this is the calculation that decides whether an FDES is an expense or an investment.

How does default data work?

The life cycle assessment (LCA) of a building subject to RE2020 adds up the impact of each product and piece of equipment installed. For each one, the consultancy looks for a declaration in the INIES database: an FDES for construction products, a PEP for equipment.

When it finds no suitable declaration, it takes default environmental data (DED). These values are developed for the ministry under a public procedure, whose version 6 dates from January 2026 and goes through the CSTB's MLab platform.

A DED is not a neutral average. It includes a safety coefficient of +30% to +100%. The principle is deliberate: an undeclared product must not be treated better than a declared one.

The gap on real cases

Using our in-house explorer of the INIES database, we compared declared products with the default data for their family. The indicator used is climate change over the whole life cycle, per functional unit.

ProductDeclared FDESDefault dataGap
Aluminium window88 kg CO2e187 kg CO2ex 2.1
Curtain wallvaries by declaration336 kg CO2eto be calculated per product

Source: INIES database, Releaf Carbon survey of October 2026, total life cycle climate change indicator.

The aluminium window says a lot. The manufacturer that published its declaration sees its product counted at less than half the default value. Its competitor with no declaration is penalised by 99 kg CO2e per window, without having done anything technically wrong.

On a multi-family housing building, multiply that by the number of windows. The gap becomes visible in the project's carbon indicator, and therefore in the design team's choice.

Why the gap weighs more on tight projects

RE2020 sets a construction carbon impact threshold (Ic construction) that tightens in stages. When a project is close to the threshold, the consultancy looks for kilos to save. Replacing default data with an FDES is often the simplest gain.

In practice, the specifier does the sorting. Between two equivalent windows, it picks the one with a declaration, because that gains margin on the threshold without changing anything in the project. The section on RE2020 in our guide EPD: definition, framework and the FDES in France goes back over this mechanism.

What changes in 2028

The RE2020 carbon threshold contains a modulation linked to the project's default data, the Mided. It depends on the Icded, the share of the impact calculated with this data, excluding lots 1, 2 and 13, compared with a pivot specific to the building use: 370 kg CO2e/m² for single-family houses, 250 for multi-family housing, 275 for offices.

Above the pivot, the annex to article R. 172-4 of the CCH (the French Construction and Housing Code) sets three periods according to the year the permit application is filed: +0.3 x (Icded - pivot) from 2022 to 2024, 0 from 2025 to 2027, then -0.3 x (Icded - pivot) from 2028.

The direction therefore reverses in 2028. A multi-family housing project with an Icded of 300 kg CO2e/m² will see its threshold fall by 15 kg CO2e/m². This modulation has not been abolished: it is worth zero until the end of 2027 and remains in the formula in force since 1 July 2026.

The government is also preparing a decree on the 2028 milestone, announced for the end of the year. As of 2 November 2026, it has not been published. We follow the subject in RE2020 2028: what changes for manufacturers.

Finally, the Rivaton report submitted on 10 July 2025 recommends keeping the negative modulation and recalculating default values from 2028. The level of DEDs may therefore move. The case for an individual declaration does not depend on that level: it reflects your real product.

Individual FDES, collective FDES or configurator?

Three options take you out of default data. They do not serve the same purpose.

OptionWho produces itWhat it reflectsWhen to choose it
Individual FDESThe manufacturerIts product, its factoryProduct better than average, sales argument
Collective FDESA trade association or groupA sector averageSmall manufacturers, limited budget
ConfiguratorA sector body, registered on INIESA product configured from a shared modelHighly variable ranges, made-to-measure

INIES has launched a new registration interface for configurators. If your sector offers one, it is often the fastest route.

A collective FDES protects you from the default value, but it does not set you apart from your competitors. If your process is less resource-intensive than average, only an individual declaration will show it in the calculation.

The forgotten lever: typical service life

A product's weight in the building's LCA also depends on its reference service life. A short service life means counting one or more replacements over the building's study period, which multiplies its impact.

We systematically compare the typical service life used in INIES for the family with the service life declared in the product's EPD. When the second is longer and justified, correcting it reduces the product's impact in the calculation without changing a line of the LCA. We give this advice at every declaration review.

What the consultancy looks at

To understand what is at stake, put yourself in the place of the person calculating the building. They work in building LCA software that draws on INIES. For each lot, they choose a data point: an individual FDES if they know the selected product, otherwise a collective FDES, and default data as a last resort.

As long as the project stays below the threshold, they look no further. When the project gets stuck, they go back through the lots one by one and replace default data with declarations. That is when they call the main contractor or the architect to find out which manufacturer has a declaration.

This is the moment when specification is decided. The manufacturer with a declaration is selected. The one without is often replaced, even when its product is technically equivalent.

The most exposed products

Not all products weigh the same in a building's LCA. The gap with default data matters most for families with a lot of mass or a lot of high-impact materials:

  • structure and structural works, in concrete, steel or timber;
  • external joinery, windows and glazed facades;
  • insulation and facade cladding;
  • HVAC equipment, declared as PEPs.

If your product belongs to one of these families and has no declaration, the gap with your declared competitors appears in almost every project.

How to estimate your own gap

The exercise takes three steps and requires no LCA.

  1. Find in INIES the default data for your product family, with its functional unit.
  2. List the FDES your competitors have already published in the same family.
  3. Compare: if the published declarations sit well below the default value, a product with no declaration is at a disadvantage in every project.

Our INIES explorer makes this comparison in a few minutes, family by family. We do it free of charge ahead of an FDES project, so that the decision rests on a figure and not on a hunch.

An archived A1 declaration counts as no declaration

This point surprises many manufacturers. INIES archives declarations prepared under the old EN 15804+A1 standard: those verified in 2021 and 2022 have been withdrawn since 1 July 2026, according to the INIES notice of 7 January 2026.

Once the declaration is archived, the consultancy can no longer use it. The product falls back on default data, with all the inflation that entails. We go through renewal in FDES verification and validity.

What a declaration costs, what its absence costs

An FDES costs €3,000 to €15,000 excl. VAT for the study at Releaf, plus verification and publication. The details are in EPD and FDES cost in 2026.

The absence of a declaration is paid for on every tender where your product is weighed with an inflated value. For a manufacturer whose products are specified on multi-family housing or offices, the trade-off rarely favours waiting.

Run the calculation for your products

Send us your product families: we will send back the gap between the default data and the published declarations, with no commitment. For the complete process, see how to obtain an FDES and our environmental declarations offer.

Frequently asked questions

  • Default environmental data (donnée environnementale par défaut, DED) is a generic value, published on INIES, that the consultancy uses under RE2020 when a product has no FDES or PEP. It is deliberately inflated by a safety coefficient so that undeclared products gain no advantage.

  • The DED development procedure applies a safety coefficient of between +30% and +100% depending on the product family. In the cases we have recorded on INIES, the gap with a declared product can exceed a factor of two.

  • Because the building's LCA then uses the value from its FDES instead of a penalising default value. The product weighs less in the carbon calculation and becomes easier to specify on a constrained RE2020 project.

  • A collective FDES, produced by a trade association or a group, avoids the default data and costs less than an individual declaration. It does, however, reflect a sector average: if your product beats that average, only an individual FDES shows it.